CN EN
  • DCL

As a part of the EV control system, DCL converts high-voltage battery voltage into low-voltage output under the control of the main controller, supplying power to low-voltage electrical equipment on the vehicle. The output terminal has a low-voltage battery; Require stable output voltage, high conversion efficiency, precise structure, compact size, high reliability, and protection functions such as input overvoltage and undervoltage, output overvoltage and undervoltage, output short circuit, input anti reverse connection, and overheating.

Product Introduction Product Parameters

As a part of the EV control system, DCL converts high-voltage battery voltage into low-voltage output under the control of the main controller, supplying power to low-voltage electrical equipment on the vehicle. The output terminal has a low-voltage battery; Require stable output voltage, high conversion efficiency, precise structure, compact size, high reliability, and protection functions such as input overvoltage and undervoltage, output overvoltage and undervoltage, output short circuit, input anti reverse connection, and overheating.

Electrical Parameters

Model DBD030-540-24 DBD030-540-12
Input Characteristics
Rated Input Voltage 540 Vdc 540Vdc
Input Voltage 450Vdc~750 Vdc 450Vdc~750 Vdc
Full Power Input Voltage Range 375Vdc ~750Vdc 415Vdc ~750Vdc
Static Loss Current (rated input, power off) ≤2mA ≤2mA
Output Characteristic
Rated Output Voltage 27Vdc 12Vdc
Rated Output Power (continuous operation) 3KW 3KW
Efficiency (at rated input and output) ≥95% ≥96%
Start the impulse current Not exceeding 1.5 times the maximum steady-state current;
Output Voltage Rise Time

Output voltage ripple (peak to peak value)

Boot Time ≤3s
Voltage stabilization accuracy ±1%
Voltage stabilization accuracy ±1%
Static loss current 2mA
(Leakage current when the input is not connected to high voltage or 14Vdc control power, and the output is connected to the battery)
Dynamic response voltage overshoot amplitude ±3%
(25%~50%~25% or 50%~75%~50% load variation, load variation rate ≤ 0.1A/us, dynamic load variation frequency 50Hz~5Hz.)
Other
Control Mode CAN enable or EN high-level enable
Grounding Output negative busbar grounding or shell bottom plate grounding;
Input continuous power on/off Under the given control signal and normal output conditions, the input can meet the requirement within 1 minute


Protection function

Model DBD030-540-24 DBD030-540-12
Output undervoltage 18-19Vdc, Self recoverable
Output overvoltage 31-32Vdc, Self recoverable
Input anti reverse connection When the input is reversed, the power supply must not be damaged;
Over Temperature Protection When the bottom plate temperature reaches 85 ± 5 ℃, the rated output will begin to decrease; Shut down when the temperature exceeds 95 ± 5 ℃; Below 85 ± 5 ℃, self recovering;
Output Current Limiting Enter the constant current mode by setting the current limit value, and reduce the rating based on the actual working temperature, input voltage, and output voltage.
Output Short Circuit Shut down; After the fault is resolved, it will self recover; Continuous short circuit for 5 times, module locked, needs to be powered on again for restoration.