CN EN
  • DCF Multi in One

DCF X in 1 products are commonly used in the field of hydrogen fuel cells, which are controllers that integrate multiple functions into one, making fuel cell system integration simpler and more efficient.

Main parts: isolated/non isolated boost DCDC+MCU+air compressor controller+DCL+PDU, etc.

产品介绍 功能参数

DCF X in 1 products are commonly used in the field of hydrogen fuel cells, which are controllers that integrate multiple functions into one, making fuel cell system integration simpler and more efficient.

Main parts: isolated/non isolated boost DCDC+MCU+air compressor controller+DCL+PDU, etc.

DC/DC Input Parameters
Input minimum voltage (V) 200
Input maximum voltage (V) 360 (Customizable input range)
Input rated current (A) 800
Input current range (A) 0-800 (Customizable)
Rated input power(kW) 184 (Customizable)
Input current control accuracy 5A-100A,≤±1A; 100A-900A,≤±1%
Input current ripple ≤1%
Input current regulation rate 4A/ms,(Software adjustable)
Dynamic response time of input current(ms) 200
DC/DC Output Parameters
Output minimum voltage(V) 450
Output the highest voltage (V) 750 (Customizable output range)
Rated power point efficiency (%) >97%
Output Voltage Ripple ≤500mV
Auxiliary Power Input Parameters
Input Voltage(V) 18-36VDC
Maximum Input Power (W) ≤120W
Functional protection Input overvoltage, input undervoltage, input overcurrent, output overvoltage, output undervoltage, output overcurrent, over temperature protection, CPU over temperature, communication interruption, high voltage interlock protection, DCDC output short circuit protection
Environment Applicability
Operation Temperature Range -40℃-75℃
Temperature range of storage environment -40℃-105℃
Humidity ≤100%,Surface condensation can work normally
Working Altitude ≤3000m
Salt Fog Neutral salt spray test, shell ≥ 48h
Noise ≤60dB
Structure and heat dissipation parameters
Housing Material Aluminum alloy ADC12 (or upon customer request)
Protection Grade IP67
Heat Dissipation Method Liquid Cooling
Heat Dissipation ≤5.2kW
Coolant inlet temperature (℃) ≤65℃
Coolant Flow Rate ≥20L/min
water resistance 15.8kPa @20L/min
Outer diameter of water nozzle 25mm & 16mm
External dimensions Determine the size based on the combination of actual application functions
Reference weight Determine based on the combination of actual application functions
Application Instructions for CAN Communication
Communication method/communication baud rate CAN2.0B/250kbps
CAN Botlade/CAN program upgrade support
Termination resistor(Ω) None (customers can configure as needed)

Email: william@bjshdt.com.cn